Battery series and parallel calculator

Enter your battery size and how many you have. The calculator shows the voltage and capacity each wiring arrangement produces, and explains why higher voltage banks need far less copper.

Input your numbers
Resulting bank
12 V / 400 Ah

Four 12 V 100 Ah batteries in parallel give 12 V at 400 Ah. Total stored energy is the same whichever way you wire them.

4,800 Wh total Parallel: capacity adds, voltage stays
Series: voltage adds 12 V 12 V = 24 V, capacity unchanged Parallel: capacity adds 100 Ah 100 Ah = 200 Ah, voltage unchanged
Either way the stored energy is identical. What changes is the current your cables must carry.

How the wiring changes the bank

Two batteries can be joined in two ways, and the choice decides voltage, current and cable size rather than total energy.

series: volts add, amp-hours stay the same parallel: amp-hours add, volts stay the same watt-hours are identical either way

Four 12 V 100 Ah batteries hold 4,800 Wh regardless of arrangement. In parallel they present 12 V at 400 Ah; in series, 48 V at 100 Ah. The energy is the same, but at 48 V the system moves that energy with a quarter of the current, which means thinner cable, smaller fuses and lower losses.

Which arrangement to choose

Higher voltage is generally better in anything but the smallest system, for exactly the reason above. A 3,000 W inverter on a 12 V bank draws around 250 A, demanding very heavy cable and careful terminal work; the same inverter on 48 V draws about 63 A. The practical guide most installers use: up to roughly 1,500 W of inverter load, 12 V is fine; 1,500 to 3,000 W favours 24 V; beyond that, 48 V.

The constraint is that your inverter, charge controller and any DC appliances must all match the bank voltage. Changing later means replacing hardware, so this is a decision to make at the start rather than to grow into.

Rules for building a healthy bank

Frequently asked questions

Can I wire batteries in series and parallel together?

Yes, and it is common: two series pairs at 24 V wired in parallel give 24 V at double the capacity. Keep every string identical in make, age and length of cable, and fuse each string separately.

Can I mix lithium and lead-acid in one bank?

No. They have different voltage curves and charging profiles, so one will be chronically over or undercharged. Systems that use both keep them as separate banks with separate charge control.

Does adding a battery to an old bank work?

With lead-acid, poorly: the old batteries drag the new one down to their level. With LiFePO4 it is more tolerant but still not ideal. Plan the final bank size at the outset, or expand within the first year or two with the same model.