Generator fuel consumption calculator

Enter your tank size, generator rating and the load you actually run. The calculator returns fuel burn per hour and runtime, and accounts for how differently conventional and inverter generators behave at light loads.

Input your numbers
Runtime on one tank
11.5 hours

Running at 50% load, a conventional generator burns about 0.44 gallons an hour.

0.44 gallons per hour Load: 50% of rating
Fuel burn against load conventional: burns fuel even when idle inverter: throttles down at light load 25% load full load
At light loads the gap is large, which is why inverter generators suit long, quiet backup duty.

How the calculation works

Fuel consumption depends far more on load than most people expect, and how it depends on load differs by generator type.

rough guide: gallons per hour = rated kW x 0.075 to 0.12 lightly loaded conventional units stay near the upper figure inverter units fall roughly in proportion to load

A conventional generator runs its engine at a fixed 3,600 rpm regardless of demand, because that is what fixes the output frequency. Whether it powers 500 W or 5,000 W, the engine spins the same, so fuel burn falls only modestly at light load. An inverter generator produces power electronically and can slow the engine when demand drops, cutting consumption and noise substantially.

Worked example

A 5,000 W conventional generator running a 2,500 W load with a 5 gallon tank:

consumption at 50% load: about 0.44 gallons per hour runtime: 5 / 0.44 = about 11.5 hours

An inverter generator of the same rating at the same load would use closer to 0.35 gallons an hour, stretching the tank past fourteen hours, and it would do so at a fraction of the noise.

Running a generator sensibly

Common mistakes

Frequently asked questions

How much fuel does a generator use per hour?

As a rough guide, a 5,000 W generator uses about 0.5 to 0.75 gallons an hour at half load, and a 3,000 W unit about 0.3 to 0.45. Diesel units are usually more economical per kWh than petrol, and inverter models better than conventional ones at light loads.

Is it cheaper to run a generator or use solar?

Over any meaningful period, solar. Fuel is a recurring cost with no end, while panels are paid once. Generators earn their place as backup for dark stretches and heavy occasional loads, not as the primary supply.

Can I run a generator all night?

Physically yes if the tank allows, but consider noise, exhaust safety and engine hours. A far better pattern is charging a battery bank during a shorter run and drawing on the bank overnight in silence.